Section PEF_Conf
## Possible values: Yes/No
Enable_PEF No
## Possible values: Yes/No
Enable_PEF_Event_Messages No
## Possible values: Yes/No
Enable_PEF_Startup_Delay No
## Possible values: Yes/No
Enable_PEF_Alert_Startup_Delay No
## Possible values: Yes/No
Enable_Alert_Action No
## Possible values: Yes/No
Enable_Power_Down_Action No
## Possible values: Yes/No
Enable_Reset_Action No
## Possible values: Yes/No
Enable_Power_Cycle_Action No
## Possible values: Yes/No
Enable_OEM_Action No
## Possible values: Yes/No
Enable_Diagnostic_Interrupt No
## Give value in seconds
Startup_Delay 75
## Give value in seconds
Alert_Startup_Delay 75
EndSection
Section Community_String
## Give valid string
Community_String
EndSection
Section Lan_Alert_Destination_1
## Possible values: PET_Trap/OEM1/OEM2
Alert_Destination_Type OEM1
## Possible values: Yes/No
Alert_Acknowledge No
## Give valid unsigned number in seconds
Alert_Acknowledge_Timeout 2
## Give valid unsigned number
Alert_Retries 3
## Possible values: Default/Backup
Alert_Gateway Default
## Give valid IP address
Alert_IP_Address 0.0.0.2
## Give valid MAC address
Alert_MAC_Address 00:00:00:00:00:00
EndSection
Section Alert_String_1
## Give valid number
Event_Filter_Number 0
## Give valid number
Alert_String_Set 0
## Give string. Max 64 chars.
Alert_String
EndSection
Section Alert_Policy_1
## Possible values: Always_Send_To_This_Destination/Proceed_To_Next_Entry/Do_Not_Proceed_Any_More_Entries/Proceed_To_Next_Entry_Different_Channel/Proceed_To_Next_Entry_Different_Destination_Type
Policy_Type Always_Send_To_This_Destination
## Possible values: Yes/No
Policy_Enabled No
## Give a valid number
Policy_Number 0
## Give a valid number
Destination_Selector 0
## Give a valid number (LAN = 1)
Channel_Number 0
## Give a valid number
Alert_String_Set_Selector 0
## Possible values: Yes/No
Event_Specific_Alert_String Yes
EndSection
Section Event_Filter_1
## Possible values: Manufacturer_Pre_Configured/Software_Configurable/Reserved1/Reserved3
Filter_Type Software_Configurable
## Possible values: Yes/No
Enable_Filter Yes
## Possible values: Yes/No
Event_Filter_Action_Alert Yes
## Possible values: Yes/No
Event_Filter_Action_Power_Off Yes
## Possible values: Yes/No
Event_Filter_Action_Reset Yes
## Possible values: Yes/No
Event_Filter_Action_Power_Cycle Yes
## Possible values: Yes/No
Event_Filter_Action_Oem Yes
## Possible values: Yes/No
Event_Filter_Action_Diagnostic_Interrupt Yes
## Possible values: Yes/No
Event_Filter_Action_Group_Control_Operation Yes
## Give a valid number
Alert_Policy_Number 2
## Give a valid number
Group_Control_Selector 2
## Possible values: Unspecified/Monitor/Information/OK/Non_Critical/Critical/Non_Recoverable
Event_Severity Information
## Specify a hex Slave Address or Software ID from Event Message or 0xFF to Match Any
Generator_Id_Byte_1 0x03
## Specify a hex Channel Number or LUN to match or 0xFF to Match Any
Generator_Id_Byte_2 0x00
## Specify a Sensor Type, For options see the MAN page
Sensor_Type Current
## Specify a Sensor Number or 0xFF to Match Any
Sensor_Number 0x03
## Specify a Event/Reading Type Number or 0xFF to Match Any
Event_Trigger 0x04
## Give a valid number
Event_Data1_Offset_Mask 0x05
## Give a valid number
Event_Data1_AND_Mask 0x06
## Give a valid number
Event_Data1_Compare1 0x07
## Give a valid number
Event_Data1_Compare2 0x08
## Give a valid number
Event_Data2_AND_Mask 0x09
## Give a valid number
Event_Data2_Compare1 0x11
## Give a valid number
Event_Data2_Compare2 0x12
## Give a valid number
Event_Data3_AND_Mask 0x13
## Give a valid number
Event_Data3_Compare1 0x14
## Give a valid number
Event_Data3_Compare2 0x15
EndSection